Product Description
1. Introduction to the FCC
The FCC is the United States Fischer Custom Communications, Inc. Abbreviation of the United States FCCIt mainly produces DC-6GHz radio frequency current probes. The FCC current probe is a product produced by the US FCC and authorized to be sold by Shenzhen EUTTEST in China. It is used for CE conduction emission and BCI current injection and current monitoring testing. The FCC Company is not the U.S. FCC Standards Commission, these are two different organizations. U.S. FCC produces current injection and monitoring probes、TEM cell for IC testing, Coupling and decoupling network CDN, ISN in line with CISPR22/32, single-phase and three-phase LISN and other equipment.
What is a current probe?
- A current probe, also called a current clamp, is a current probe used in electromagnetic compatibility measurement and testing. The principle of current probe is based on the theoretical basis of Faraday's Law and Lenz's Law.
- Current probes are generally used for closed-loop and open-loop testing of BCI automotive electronics high-current injection.
- The US FCC has two types of current probes and injection pliers, including:
-
-
- 2. BCI high current-injection current probe: Inject interference into the cable
- Calibration fixture-injection probe
- ————————————————————————————————
- 3. EMI-monitoring current probe: measuring interference on cables
- Calibration fixture-monitoring probe
-
Both are simply sandwiched on the cable under test, and high-frequency current interference signals can be injected or high-frequency current interference on the object to be tested in the EUT can be tested.。
This page mainly lists allBCI closed loop method and open loop methodFor a list of current probe models, please contact EUTTEST for product quotation.,
EUTTEST is an authorized agency supplier of the U.S. FCC.
2. US FCC-BCI high current injection probe
2.1. Current INJECTION PROBES equipment list AND technical parameters CURRENT INJECTION PROBES
- The FCC current injection probe meets the following standards:DO-160 E/F/G: Environmental conditions and test procedures for airborne equipment、
- IEC 61000-4-6: Conducted harassment immunity test for radio frequency field induction、
- MIL-STD 461 / GJB151B / GJB151A, GJB152B: Military electromagnetic compatibility、
- ISO11452-4: Automotive electronics BCI high current injection open/closed loop test.
Use CTRL+F to search for the models you need and provide them to us to get quotation information.
Click on the model to view the detailed product technical parameters. For unlinked models, please contact EUTTEST to obtain them.
Product model Product model | Available frequency Usable Frequency | rated power RATED WATTS (CW) | Insertion loss-typical value High EFFICIENCY BANDPASS INSERTION LOSS/FREQ | Inner ring diameter INNER DIAMETER(mm) | Outer ring diameter Outer DIAMETER(mm) | height Height mm | Calibration fixture Calibration Fixture |
F-170701-1008-1 | 10MHz – 400MHz | 1000 | <8dB / 10MHz – 400MHz | 40 | 127 | 70 | FCC-BCICF-1 |
F-170501-1008-1 | 10MHz – 400MHz | 2500 | <7dB / 10MHz – 400MHz | 40 | 127 | 134 | F-170421-1008-1 |
F-161012-1008-1 | 10kHz – 10MHz | 2500 | <7dB / 200kHz – 10MHz | 54 x 108 | 203 x 305 | 241 | F-161012-1008-2 |
F-080915-1008-1 | 3GHz – 4GHz | 100 | <8dB / 3.2GHz – 3.9GHz | 32 | 53 | 10 | F-080915-1008-2 |
F-120501-1008-1 | 1kHz – 10MHz | 1000 | <9dB / 500kHz – 10MHz | 40 x 91 | 152 x 286 | 191 | F-120501-1008-2 |
F-120-7B | 10kHz – 400MHz | 125 | <10dB / 1MHz – 400MHz | 65 | 142 | 54 | FCC-BCICF-3 |
F-080409-1008-1 | 2.0 GHz – 3GHz | 100 | <9dB / 2GHz – 3.0GHz | 32 | 71 | 19 | F-080409-1008-2 |
F-120-8F | 10kHz – 400MHz | 250 | <5dB / 500kHz – 200MHz | 40 | 127 | 134 | *, F-170421-1008-1, FCC-BCICF-4 |
F-150-2 | 800MHz – 2.1GHz | 250 | <9dB / 800MHz – 2.1 GHz | 40 | 98 | 38 | FCC-BCICF-150-2 |
F-140-HV | 100kHz – 400MHz | 5kV Peak Pulse | <7dB / 2MHz – 300MHz | 40 | 127 | 70 | FCC-BCICF-1-HV |
F-080728-1008-1 | 500MHz – 1GHz | 250 | <7dB/500MHz – 800MHz | 65 | 142 | 54 | F-080728-1008-2 |
F-150-1 | 2.3GHz – 7.0GHz | 100 | <9dB/2.3GHz – 7GHz | 12 | 33 | 13 | FCC-BCICF-150-1 |
F-070601-1008-1 | 400MHz – 1GHz | 250 | <7dB/450MHz – 1GHz | 40 | 127 | 70 | F-070601-1008-2 |
F-150 | 800MHz – 2.1GHz | 250 | <7dB/950MHz – 2.0GHz | 32 | 98 | 38 | FCC-BCICF-150 |
F-130A-1 | 1MHz – 400MHz | 100 | <7dB/3MHz – 350MHz | 40 | 127 | 70 | FCC-BCICF-1 |
F-130-3 | 1MHz – 400MHz | 100 | <7dB/3MHz – 200MHz | 65 | 142 | 54 | FCC-BCICF-3 |
F-140 | 1MHz – 1GHz | 100 | 40 | 127 | 70 | FCC-BCICF-2 | |
F-120-9A | 10kHz – 230MHz | 125 | <8dB/150kHz – 100MHz | 40 | 127 | 134 | FCC-BCICF-6-150 |
F-120-6A | 10kHz – 400MHz | 100 | <7dB/700kHz – 200MHz | 40 | 127 | 70 | FCC-BCICF-1 |
F-120-9 | 10kHz – 230MHz | 100 | <11dB/150kHz – 230MHz | 40 | 127 | 70 | FCC-BCICF-1 |
F-120-8 | 10kHz – 400MHz | 200 | <7dB/800kHz – 300MHz | 40 | 127 | 134 | *, F-170421-1008-1, FCC-BCICF-4 |
F-120-5 | 10kHz – 100MHz | 100 | <10dB/500kHz – 1MHz | 65 | 142 | 53 | FCC-BCICF-3 |
F-191011-1008-1 | 10kHz – 500MHz | 200 | <10dB/150kHz – 500MHz | 50 | 137 | 70 | F-191011-1008-2 |
F-180101-1008-1 | 10kHz – 400MHz | 125 | <10dB/10kHz – 400MHz | 40 | 127 | 70 | FCC-BCICF-1 |
*:Selected according to test criteria, contact us for more information
2021 new product: Injection probe F-191011-1008-1 , With current monitoring probe F-180419-1005-1 .
2.2. Bulk Current Injection Probe Fixtures: BCI Current Injection Probe metering and calibration fixtures purchase model
The FCC current injection probe and current monitoring probe calibration fixture meet the requirements of the following standards, and the probe and calibration fixture can be directly provided to the Institute of Metrology for annual measurement services. Contact EUTTEST for details.
DO-160 C,D,E,F,G、MIL-STD 461 C,D,E,F、J-1113-4、ISO11452-4;
Calibration fixture model | Matching current injection probe models |
F-040128-1008-2A | F-040128-1008-1A |
F-070601-1008-2 | F-070601-1008-1 |
F-080409-1008-2 | F-080409-1008-1 |
F-080728-1008-2 | F-080728-1008-1 |
F-080915-1008-2 | F-080915-1008-1 |
F-120501-1008-2 | F-120501-1008-1 |
F-161012-1008-2 | F-161012-1008-1 |
F-170421-1008-1 | F-120-8, F-120-8F, F-170501-1008-1 |
FCC-BCICF-1 | F-120-1, F-120-2, F-120-3, F-120-3B, F-120-6A, F-120-9, F-120-9B, F-130-1, F-130A, F-130A-1 |
FCC-BCICF-1-HV | F-140-HV |
FCC-BCICF-150 | F-150 |
FCC-BCICF-150-1 | F-150-1 |
FCC-BCICF-150-2 | F-150-2 |
FCC-BCICF-2 | F-140A-1 |
FCC-BCICF-2-1 | F-070601-1008-1 |
FCC-BCICF-3 | F-120-5, F-130-3 |
FCC-BCICF-4 | F-120-3A, F-120-3A-1, F-120-8, F-120-8F, F-120-8G, F-120-9A, F-130-2 |
FCC-BCICF-4-HV | F-120-8-HV |
FCC-BCICF-6-150 | F-120-9A |
3. U.S. FCC-EMI Monitoring Current Monitor Probes:
3.1. Current monitoring probe equipment list and technical parameters Monitor Probes:
The FCC current monitoring probe meets the following standards. The current monitoring probe can only measure small signals. Please do not use it for large-signal testing!
The current monitoring probe is suitable for the following standards: CISPR 22/32、CISPR 25 current method CE test is transmitted to the transmitter、DO-160 C,D,E,F、IEC 61000-4-6、MIL-STD 461 C,D,E,F、J-1113-2、J-1113-4、ISO11452-4 high current injection monitoring probe, BCI closed loop method test requires、1752-2.
Use CTRL+F to search for the models you need and provide them to us to get quotation information.
Click on the model to view the detailed product technical parameters. For unlinked models, please contact EUTTEST to obtain them.
Model number PRODUCT | Available frequency Frequency | A Inner ring diameter | B Outer ring diameter | C height (mm) | ZTΩ | DBΩ | connector Connector | maximum 电流 <400Hz | RF (CW) | pulse peak | Calibration fixture |
F-10 | 10Hz -2MHz | 32 | 94 | 64 | 0.25 | -12 | N | 350 | 100 | 100 | FCC-MPCF-1-32/94/64 |
F-10-1 | 10Hz -2MHz | 32 | 94 | 64 | 0.03 | -30 | N | 50 | 25 | 500 | FCC-MPCF-1-32/94/64 |
F-10A | 10Hz – 2MHz | 67 | 142 | 53 | 0.25 | -12 | N | 350 | 100 | 100 | FCC-MPCF-1-32/94/64 |
F-10A-1 | 10Hz – 2MHz | 67 | 142 | 53 | 0.03 | -30 | N | 50 | 25 | 500 | FCC-MPCF-1-32/94/64 |
F-12 | 10Hz – 3MHz | 32 | 94 | 64 | 0.32 | -10 | N | 350 | 100 | 100 | NULL |
F-14 | 10 Hz – 500 kHz | 32 | 94 | 64 | 0.12 | -18 | N | 400 | 50 | 500 | FCC-MPCF-1-32/94/64 |
F-14-1 | 10 Hz – 500 kHz | 32 | 94 | 64 | 0.02 | -33 | N | 400 | 25 | 500 | FCC-MPCF-1-32/94/65 |
F-14-C | 10 Hz – 2 MHz | 32 | 98 | 38 | 0.03 | -30 | N | 50 | 10 | 100 | FCC-MPCF-2-32-40/98/38 |
F-14A | 10 Hz – 500 kHz | 67 | 142 | 53 | 0.12 | -18.5 | N | 400 | 50 | 500 | FCC-MPCF-2-67/142/53 |
F-14A-1 | 10 Hz – 500 kHz | 67 | 142 | 53 | 0.03 | -30.5 | N | 400 | 25 | 500 | FCC-MPCF-2-67/142/54 |
F-16 | 10 Hz – 70 MHz | 32 | 94 | 64 | 4 | 12 | N | 400 | 50 | 300 | FCC-MPCF-1-32/94/64 |
F-16-1 | 10 Hz – 70 MHz | 32 | 94 | 64 | 0.5 | -6 | N | 400 | 3 | 300 | FCC-MPCF-1-32/94/64 |
F-16A | 10 Hz – 70 MHz | 67 | 142 | 53 | 4 | 12 | N | 50 | 50 | 300 | FCC-MPCF-2-67/142/53 |
F-16A-1 | 10 Hz – 70 MHz | 67 | 142 | 53 | 0.5 | -6 | N | 400 | 3 | 300 | FCC-MPCF-2-67/142/53 |
F-16M | 100 Hz – 50 MHz | 32 | 98 | 38 | 0.5 | -6 | N | 400 | 2 | 50 | FCC-MPCF-2-67/142/54 |
F-170302-1005-1 | 10Hz – 50MHz | 40 | 80 | 19 | 0 | -60 | N | 20 | 2 | 2000 | FCC-MPCF-3-32-40/71/19 |
F-170308-1005-1 | 10Hz – 50MHz | 67 | 142 | 53 | 0.7 | -3 | N | 50 | 2 | 100 | FCC-MPCF-2/67/142/53 |
F-170317-1005-1 | 100kHz – 300MHz | 305 | 394 | 51 | 3.5 | 11 | N | 1000 | 2 | 100 | FCC-MPCF-1-127/197/41 |
F-170329-1005-1 | 10kHz – 30MHz | 67 | 142 | 53 | 1.4 | 3 | N | 1000 | 2 | 100 | FCC-MPCF-2/67/142/53 |
F-170705-1005-1 | 100kHz – 30MHz | 67 | 142 | 53 | 2 | 6 | N | 750 | 2 | 100 | FCC-MPCF-2/67/142/53 |
F-170710-1005-1 | 10kHz – 400MHz | 32 | 71 | 19 | 0.35 | -9 | N | 50 | 2 | 100 | FCC-MPCF-3-32/71/19 |
F-170804-1005-1 | 10kHz – 400MHz | 65 | 104 | 19 | 5 | 14 | N | 150 | 2 | 100 | FCC-MPCF-2-67/142/53 |
F-180419-1005-1 | 10kHz – 500MHz | ** | ** | ** | ** | ** | ** | ** | ** | ** | F-191011-1008-2 |
F-180907-1005-1 | 10kHz – 108MHz | 127 | 197 | 41 | 5.6 | 15 | N | 500 | 100 | 100 | FCC-MPCF-1-127/197/41 |
F-180907-1005-2 | 10kHz – 108MHz | 127 | 197 | 41 | 1 | Ø | N | 500 | 10 | 10 | FCC-MPCF-1-127/197/41 |
F-180907-1005-3 | 10Hz – 1MHz | 127 | 147 | 41 | 0.1 | -20 | N | 1000 | 10 | 100 | FCC-MPCF-1-127/197/41 |
F-200925-1005-1 | 10kHz – 1GHz | 32 | 71 | 19 | — | — | N | 100 | 3 | / | / |
F-2000-12mm | 10MHz – 3GHz | 13 | 37 | 13 | 16 | 24 | SMA | 100 | 10 | 50 | FCC-MPCF-2K Rev B |
F-2000-32mm-1 | 10MHz – 2.1GHz | 32 | 71 | 19 | 18 | 22 | N | 350 | 3 | 100 | F-050315-1005-1 |
F-2000-32mm-2 | 10MHz – 3GHz | 32 | 71 | 19 | 18 | 22 | N | 350 | 3 | 100 | F-050315-1005-2 |
F-2000-40mm-1 | 10MHz – 2.1GHz | 40 | 80 | 19 | 18 | 25 | N | 350 | 2 | 100 | FCC-MPCF-F-2000-40mm |
F-33-1 | 10 kHz – 250 MHz | 32 | 71 | 19 | 6.3 | 16 | BNC* | 100 | 10 | 50 | FCC-MPCF-3-32/71/19 |
F-33-2 | 1 kHz – 250 MHz | 32 | 71 | 19 | 1 | Ø | BNC* | 100 | 2 | 50 | FCC-MPCF-3-32/71/19 |
F-33-3 | 1 kHz – 200 MHz | 32 | 71 | 19 | 4 | 12 | BNC* | 100 | 10 | 50 | FCC-MPCF-3-32/71/19 |
F-33-5 | 10 kHz – 140 MHz | 20 | 51 | 13 | 1.3 | 2.3 | SMA | 25 | 10 | 50 | FCC-MPCF-3-32/71/19 |
F-33-6 | 1 kHz – 200 MHz | 3 | 19 | 19 | 0.8 | -2 | SMA | 5 | 1 | 10 | FCC-MPCF-3-32/71/19 |
F-35 | 100 Hz – 100 MHz | 32 | 98 | 38 | 1 | 0 | N | 200 | 3 | 100 | FCC-MPCF-2-32-40/98/38 |
F-35A | 100 Hz – 100 MHz | 32 | 98 | 38 | 1 | 0 | N | 200 | 3 | 100 | FCC-MPCF-2-32-40/98/38 |
F-35-1 | 10 kHz – 100 MHz | 32 | 98 | 38 | 0.15 | -16.5 | N | 100 | 6 | 500 | FCC-MPCF-2-32-40/98/38 |
F-35A-L | 100Hz – 100MHz | 32 | 98 | 38 | 1 | Ø | N | 200 | 3 | 100 | FCC-MPCF-2-32-40/98/38 |
F-37-2 Clip-On | 100kHz – 1GHz | 12 | 81 | 19 | 1 | Ø | SMA | 100 | 3 | 100 | FCC-MPCF-37-2 |
F-38-1 Clip-On | 10kHz – 200MHz | 5 | 54 | 10 | 2.8 | 9 | SMA | 20 | 1 | 10 | FCC-MPCF-F-38 |
F-38-2 Clip-On | 1kHz – 200MHz | 5 | 54 | 10 | 1 | Ø | SMA | 20 | 1 | 10 | FCC-MPCF-F-38 |
F-38-4 Clip-On | 1MHz – 1GHz | 5 | 54 | 10 | 5.6 | 15 | SMA | 20 | 1 | 10 | FCC-MPCF-F-38 |
F-39-1 | 10 kHz – 200 MHz | 18 | 85 | 6 | 2.8 | 9 | SMA | 20 | 1 | 10 | FCC-MPCF-39 |
F-39-2 | 1 kHz – 200 MHz | 18 | 85 | 6 | 1 | Ø | SMA | 20 | 1 | 10 | FCC-MPCF-39 |
F-39-4 | 1 MHz – 1 GHz | 18 | 85 | 6 | 5.6 | 15 | SMA | 20 | 1 | 10 | FCC-MPCF-39 |
F-40 | 10 Hz – 50 MHz | 67 | 153 | 102 | 0.1 | -20 | N | 350 | 100 | 200 | FCC-MPCF-2-32-40/98/38 |
F-40-5 | 10 Hz – 50 MHz | 67 | 153 | 102 | 0.1 | -20 | N | 1000 | 100 | 5000 | FCC-MPCF-2-67/142/53 |
F-42 | 1kHz – 100MHz | 32 | 98 | 38 | 6 | 15.5 | N | 350 | 50 | 100 | FCC-MPCF-2-32-40/98/38 |
F-42A | 1kHz – 100MHz | 32 | 71 | 19 | 4 | 12 | N | 50 | 2 | 100 | FCC-MPCF-3-32/71/19 |
F-50 | 100 kHz – 500 MHz | 32 | 71 | 19 | 9 | 19 | BNC* | 300 | 20 | 50 | FCC-MPCF-3-32/71/19 |
F-51 | 10 kHz – 500 MHz | 32 | 98 | 38 | 10 | 20 | N | 350 | 50 | 100 | FCC-MPCF-3-32/71/19 |
F-52 | 10 kHz – 500 MHz | 40 | 117 | 38 | 10 | 20 | N | 350 | 50 | 100 | FCC-MPCF-3-32-40/71/19 |
F-55 | 10 kHz – 500 MHz | 32 | 98 | 38 | 1 | 0 | N | 350 | 3 | 100 | FCC-MPCF-3-32/71/19 |
F-52B | 10kHz – 400MHz | 40 | 80 | 19 | 4.5 | 13 | N | 200 | 2 | 100 | FCC-MPCF-3-32-40/71/19 |
F-55A | 1 kHz – 500 MHz | 32 | 71 | 19 | 0.1 | -20 | N | 350 | 10 | 100 | FCC-MPCF-3-32/71/19 |
F-57 | 1kHz – 500MHz | 40 | 98 | 38 | 1 | Ø | N | 200 | 2 | 100 | FCC-MPCF-2-32-40/98/38 |
F-61 | 1MHz-1GHz | 32 | 71 | 19 | 16 | 24 | BNC* | 200 | 20 | 50 | FCC-MPCF-2/19/58/26 |
F-62 | 10MHz-1GHz | 32 | 71 | 19 | 13 | 22 | BNC* | 200 | 20 | 50 | FCC-MPCF-3-32/71/19 |
F-65 | 100 kHz – 1 GHz | 32 | 71 | 19 | 1 | Ø | N | 350 | 3 | 100 | FCC-MPCF-3-32/71/19 |
F-65A | 10 kHz – 1 GHz | 32 | 71 | 19 | 0.1 | -20 | N | 350 | 10 | 100 | FCC-MPCF-3-32/71/19 |
F-75B | 1kHz – 500MHz | 70 | 125 | 38 | 1 | Ø | N | 250 | 2 | 100 | FCC-MPCF-2/70/125/38 |
F-70 | 1 kHz – 100 MHz | 70 | 125 | 38 | 1 | 0 | N | 350 | 3 | 100 | FCC-MPCF-2-70/125/38 |
F-71 | 10 kHz – 500 MHz | 70 | 125 | 38 | 8 | 18 | N | 200 | 25 | 50 | FCC-MPCF-2-70/125/38 |
F-72 | 100 Hz- 100 MHz | 67 | 142 | 53 | 5 | 14 | N | 350 | 100 | 100 | FCC-MPCF-2-67/142/53 |
F-72-1 | 100 Hz- 100 MHz | 67 | 142 | 53 | 0.15 | -16 | N | 150 | 12 | 500 | FCC-MPCF-2-67/142/53 |
F-72-2 | 100 Hz- 100 MHz | 67 | 142 | 53 | 0.01 | -46 | N | 70 | 60 | 5,000 | FCC-MPCF-2-67/142/53 |
F-72-7 | 10Hz-200MHz | 67 | 142 | 53 | 0.01 | -44 | N | 200 | 60 | 5,000 | FCC-MPCF-2-67/142/54 |
F-73 | 10 Hz- 30 MHz | 67 | 142 | 53 | 2 | 6 | N | 350 | 200 | 200 | |
F-75 | 10 kHz – 500 MHz | 70 | 125 | 38 | 1 | 0 | N | 350 | 3 | 100 | FCC-MPCF-2-70/125/38 |
F-80 | 1 kHz – 100 MHz | 127 | 197 | 41 | 5 | 14 | N | 350 | 100 | 100 | FCC-MPCF-1-127/197/41 |
F-80-1 | 1 kHz – 100 MHz | 127 | 197 | 41 | 1 | 0 | N | 350 | 2 | 100 | FCC-MPCF-1-127/197/41 |
F-81 | 100 Hz- 10 MHz | 127 | 197 | 41 | 1 | 0 | N | 350 | 100 | 100 | FCC-MPCF-1-127/197/41 |
F-2000 | 10 MHz – 3 GHz | 13 | 37 | 17 | 16 | 24 | SMA | 100 | 10 | 50 | FCC-MPCF-36 Rev B |
2021 new product: F-180419-1005-1
Discontinued models that are not updated in time: F-52 | F-61
3.2. BCI closed loop method, current monitoring probe calibration fixture
Calibration fixture model | Matching current monitoring probe models |
F-080902-1005-2 | F-72-8 |
FCC-MPCF-1-127/197/41 | F-80, F-80-1, F-81 |
FCC-MPCF-1-32/94/64 | F-10, F-10-1, F-12, F-14, F-14-1, F-16, F-16-1 |
FCC-MPCF-2-32-40/71/19 | F-171221-1005-1, F-33-1, F-33-1-40mm, F-33-2, F-52B |
FCC-MPCF-2-32-40/98/38 | F-14C, F-16B, F-16M, F-35, F-35-1, F-35A-L, F-40, F-42, F-51, F-52, F-57 |
FCC-MPCF-2-67/142/53 | F-10A, F-10A-1, F-14A, F-14A-1, F-16A, F-16A-1, F-170804-1005-1, F-40-5, F-72, F-72-1, F-72-2, F-72-7, F-73 |
FCC-MPCF-2-70/125/38 | F-70, F-71, F-75 |
FCC-MPCF-2K | F-2000 |
FCC-MPCF-2K Rev B | F-2000-12mm |
FCC-MPCF-3-32-40/71/19 | F-33-1-40mm, F-51A, F-51B, F-52B, F-61-40mm |
FCC-MPCF-3-32/71/19 | F-2000-32mm-1, F-2000-32mm-2, F-33-1, F-33-2, F-33-3, F-33-4, F-42A, F-50, F-51A, F-55, F-55A, F-60, F-61, F-62, F-62A, F-65, F-65A |
FCC-MPCF-33-5 | F-33-5 |
FCC-MPCF-36 Rev B | F-36-1 Clip-On, F-36-2 Clip-On, F-36-4 Clip-On |
FCC-MPCF-37-2 | F-37-2 Clip-On |
3.3. Surface current probe
Model number PRODUCT | Available frequency Frequency | A available Inner height | B available Inner width | C Outer height | D Outer width | E Foreign trade degree | ZTΩ | DBΩ | connector Connector | maximum current DC-60 Hz | maximum 电流 <400Hz | RF (CW) | pulse peak |
F-32-9B | 100kHz-300MHz | 6 | 152 | 46 | 28 | 121 | 3.2 | 10 | SMA | 100 | 100 | 10 | 100 |
Model number PRODUCT | Available frequency Frequency | A horizontal diameter | B Vertical radius | C thickness (mm) | ZTΩ | DBΩ | connector Connector | maximum current DC-60 Hz | maximum 电流 <400Hz | RF (CW) | pulse peak |
F-90 | 10 kHz – 1 MHz | 89 | 51 | 38 | 0.08 | -22 | N | 5000 | 300 | 10 | 200 |
F-91 | 1 MHz – 100 MHz | 89 | 51 | 38 | 1.4 | 3 | N | 5000 | 300 | 20 | 200 |
F-92 | 10 MHz – 400 MHz | 76 | 44 | 38 | 0.9 | -1 | BNC | 5000 | 300 | 10 | 200 |
F-96 | 1 MHZ – 450 MHz | 19 | 13 | 10 | 1.26 | 2 | SMA | 10 | 10 | 10 | 100 |
F-97 | 10 MHz – 1.5 GHz | 10 | 13 | 8 | 0.45 | -7 | SMA | 10 | 10 | 10 | 100 |
Model number PRODUCT | Available frequency Frequency | A available Inner diameter | B Foreign trade degree | C Outer width | D Outer height | ZTΩ | DBΩ | connector Connector | maximum current DC-60 Hz | maximum 电流 <400Hz | RF (CW) | pulse peak |
F-36-1 | 10 kHz – 200 MHz | 5 | 54 | 13 | 19 | 4 | 12 | SMA | 20 | 20 | 1 | 10 |
F-36-2 | 1 kHz – 200 MHz | 5 | 54 | 13 | 19 | 1 | 0 | SMA | 20 | 20 | 1 | 10 |
F-36-4 | 1 MHz – 1 GHz | 5 | 54 | 13 | 19 | 22 | 27 | SMA | 20 | 20 | 1 | 10 |
The principle of current probe?
①. When high-frequency current is injected, the current enters the PCB through the wire and affects the normal function of the PCB through conduction, capacitive coupling, etc. This is a limit point in the EMC test.
②. When the EUT cable is clamped for testing, the high-frequency current conducted by the PCB on the cable is coupled to the monitoring current probe, and then transmitted through the coaxial cable to the EMI test receiver to display the current spectrum map to evaluate whether the high-frequency interference released by the EUT during normal operation is within the limit range required by the standard..
Can't use it? Click to view-"How to use the injection current probe and monitoring current probe?"
FCC current probe product coverage standard
The products of the U.S. FCC company meet the following standards
IEC/EN 61000-4-6 / MIL-STD-461/462 / The pulse generator/electromagnetic pulse test system of EN55022/CISPR 22/CISPR32 standard/MIL-STD-188-125 is used to verify whether sensitive electronic equipment can withstand electromagnetic pulses, high-power microwaves, and other electromagnetic threats.
Transient protection device:Transient protection device or surge suppressor is used to protect sensitive electronic communication equipment from lightning, electromagnetic pulse, high-power microwave and other electromagnetic threats. Surge suppressor models are available for frequencies above 3 GHz.
Data line suppressor:Can be used for 10/100/1000 Base T system.
EUTTEST Service:
Our company sells FCC current probes in civil Electronics (such as cispr32), aerospace (do160 \ mil-std-461), vehicle and ship (mil-std-461), automotive electronics (CISPR25) and other fields to provide complete transmission impedance parameters, which is easy to be used in the test software to achieve automatic testing. In addition, eutest provides after-sales installation and training services for FCC current probes sold.