R&S ESRP Pre-Certified EMI Receiver 9kHz-3GHz-7GHz

Order Number: EUTS0653

Min. order: 1 Unit
Stock: 0
Delivery: 14 weeks

Standards: Common Test Standards
Industry: General Electronics

Warranty: Original Import ; New Products ; Authorized Sales
Training: On-site training; Telephone; Email
Logistics: Shenzhen to National
Payment: Internet Banking T/T

Product Price:

Product Description:

R&S ESRP EMI test receiver is produced by Germany R&S and sold by Shenzhen EUTTEST agent products, ESRP can be used for 3.6GHz or 7GHz conducted and radiated emissions test, EUTTEST has a wealth of on-site debugging experience, can be set up for you!Test systems that comply with EMC standards for each productThe

Feature Description:

The ESRP is designed for diagnostic measurements during development and pre-compliance measurements to prepare products for final certification testing. It measures electromagnetic interference in the frequency range from 10Hz to 7GHz using either conventional step frequency sweeps or FFT-based time domain sweeps, a method that significantly speeds up measurements. At the same time, the ESRP is a full-featured, powerful laboratory signal and spectrum analyzer.The ESRP comes with a simple menu structure combined with an intuitive touch screen that makes theEMI TestingVery easy to operate in any mode.

Results of EMI final measurement with R&S ESRP receiver

Results of EMI final measurement with R&S ESRP receiver

R&S ESRP Product Technical Data:

“Reminder: swipe tables left and right”
frequency
Frequency range
R&S-ESRP3
9 kHz to 3.6 GHz
 
R&S-ESRP3 (R&S-ESRP-B29 option)
10 Hz to 3.6 GHz
 
R&S-ESRP7
9 kHz to 7 GHz
 
R&S-ESRP7 (R&S-ESRP-B29 option)
10 Hz to 7 GHz
power level (elec.)
Maximum Input Level
AC coupling
50V
DC coupling
0V
Maximum RF level (continuous wave)
RF attenuation ≥ 10 dB;
Turn off the RF preamplifier
RF attenuation ≥ 10 dB;
Open RFPreamplifier
euttest
30 dBm (= 1 W)
euttest
23 dBm (= 0.2 W)
Maximum pulse voltage
RF attenuation ≥ 10 dB
150 V
R&S authorized sales agent in China
Euttest.com
Maximum pulse energy
RF attenuation ≥ 10 dB; 10 μs
1 mWs
1 dB compression
RF attenuation 0 dB;
Turns off the RF preamplifier as well as the preselection
+3 dBm, nominal
IF and resolution bandwidth
 
Analyzer mode (≥ 10 Hz) and receiver mode
10 Hz to 10 MHz (-3 dB) in 1/2/3/5/10 steps
 
Analyzer and receiver mode
200 Hz, 9 kHz, 120 kHz (-6 dB),
1 MHz (pulse bandwidth)
 
With R&S-ESRP-B29 option (in analyzer as well as receiver mode)
Increase 10 Hz to 100 kHz
(-6 dB), in decimal steps
Preselection (R&S-ESRP-B2 option)
Can be turned off in analyzer mode
16 fixed filters
Preamplifier
(R&S-ESRP-B2 option)
Can be turned on/off
1 kHz to 7 GHz, 20 dB gain, nominal
measuring time
Analyzer mode (scan time)
 
 
Frequency span = 0 Hz
1 μs to 16 000 s
 
Frequency span ≥ 10 Hz (scanning)
1 ms to 16 000 s
 
Frequency span ≥ 10 Hz (FFT)
7 μs to 16 000 s
 
Receiver mode (stepped frequency sweep)
50 μs to 100 s (depending on frequency)
 
Receiver mode (time domain scanning)
50 μs to 100 s (depending on frequency subrange)
frequency step
Receiver mode (stepped frequency sweep)
Minimum 1 Hz euttest
 
Receiver mode (time domain scanning)
0.25 × IF bandwidth
oscillograph
receiver mode
Maximum Peak, Minimum Peak, Quasi-Peak, Root Mean Square, Mean, Mean with Measurement Time Constant (CISPR Mean), RMS Mean (CISPR-RMS)
Display Average Noise Level (DANL)
Receiver Mode, Nominal, Average Detector (AV), RF Attenuation 0 dB, Terminated 50 Ω
 
Turn off the RF preamplifier
 
 
500 MHz with 120 kHz bandwidth
< 6 dBμV
 
3 GHz, 1 MHz bandwidth
< 17 dBμV
 
Turn on the RF preamplifier
 
 
500 MHz with 120 kHz bandwidth
< -7 dBμV
 
3 GHz, 1 MHz bandwidth
< 5 dBμV
Number of scanning (trace) points
 
Analyzer mode (standard)
101 to 32 001
 
Analyzer Mode (EMI)
101 to 200 001
 
receiver mode
Maximum 4 000 000
Overall measurement uncertainty
Continuous Wave Signal, Level 0 dB to -70 dB (below reference level), S/N > 20 dB, Auto Sweep Time, RF Attenuation 10 dB, 20 dB, 30 dB, 40 dB, Preselection On, Span/RBW <100, 95% Confidence, +20°C to +30°C
 
9 kHz ≤ f < 3.6 GHz
0.47 dB
 
3.6 GHz ≤ f ≤ 7 GHz
0.57 dB
“Reminder: swipe tables left and right”

ESRP receivers come standard and optional:

“Reminder: swipe tables left and right”
ESRP Standard
Model number
part number
EMI Test Receiver, 9 kHz to 3.6 GHz
R&S-ESRP3
1316.4500.03
EMI Test Receiver, 9 kHz to 7 GHz
R&S-ESRP7
1316.4500.07
Annexes provided
Power cord, euttest.com, probe power adapter cable, quick start guide and CD-ROM
(with operating and service manuals)
ESRP Software Options
time domain scan
R&S-ESRP-K53
1316.4639.02
IF analysis
R&S-ESRP-K56
1316.4897.02
ESRP Hardware Options
Ruggedized housing
R&S FSV-B1
1310.9500.02
Preselection and RF Preamplifier
R&S-ESRP-B2
1316.4700.02
OCXO, precision reference frequency
R&S FSV-B4
1310.9522.02
OCXO, enhanced frequency stability euttest
R&S FSV-B4
1310.9522.03
Tracking Generator, 9 kHz to 7 GHz
R&S FSV-B9
1310.9545.02
Solid State Drives (SSD, removable)
R&S-ESRP-B18
1316.3555.03
Spare hard disk drive (HDD, removable)
R&S-ESRP-B19
1316.3561.03
RF Preamplifier (100 kHz to 7 GHz)
R&S FSV-B22
1310.9600.02
Frequency extension 10 Hz including EMI bandwidth in decimal steps
R&S-ESRP-B29
1316.4880.02
DC power supply, 12 V to 15 V
R&S FSV-B30
1310.9897.02
Lithium-ion battery packs
R&S FSV-B32
1321.3750.02
“Reminder: swipe tables left and right”

 

Order No. EUTS0653

Entered. 0/100

Sales Hotline:13425158926

Sales mailbox:sales@euttest.com

Sales WeChat account: euttest

EUTTEST-inquiry-wechat Shenzhen EUTTEST Technology Co.

Contact Sales by WeChat

Sales QQ:3127609248

[882] DISCLAIMER: Reproduction and redistribution by anyone without written permission from EUTTEST is prohibited.

Product parameters are subject to the manufacturer's final version.

If you like our products, please press Ctrl + D shortcut to favorite this product.