F-230511-1008-1 FCC BCI Current Probe

Order Number: EUTS0878
Test frequency: 4kHz - 10MHz
Brand: FCC

Min. order: 1 Unit
Stock: 0
Delivery: 16 weeks

Standards: Common Test Standards
Industry: General Electronics

Warranty: Original Import ; New Products ; Authorized Sales
Training: On-site training; Telephone; Email
Logistics: Shenzhen to National
Payment: Internet Banking T/T

Product Price:

Product Description:

F-230511-1008-1 is the United States FCC BCI current probe products, can be in the EMC laboratory for your electronic products injected into the maximum 3000W power, the EUT under common mode mode current up to 2000 amperes, and also has a 258 mm large diameter, can be said to be the power and the size of the cable to be tested to achieve the ultimate current injection probe products! It can be said to be one of the current injection probes that maximize both power and cable size.

Because of the large size of the clampable cable and therefore the size of the probe itself, it can only be used in the 10 MHz frequency range. If you need to inject large currents at higher frequencies, please choose the FCC F-230523-1008-1, F-140 For higher frequency current injection probes, please contact us for a recommendation of the right product for you.

Technical parameters:

Product Specification Sheet:

“Reminder: swipe tables left and right”
Model:
F-230511-1008-1
Manufacturer:
Fischer Custom Communications, Inc.
China Agent:
Shenzhen EUTTEST
Test frequency range:
4 kHz - 10MHz
Inside Dimensions:
258 mm
Outside Dimensions:
102 mm
Height:
112 mm
Rated input power:
3000W@30min
Rated input current:
Common mode: 2000A
Differential mode: 1000A
Optional accessories:
Calibration Fixture: F-120501-1008-2
Insertion Loss:
-38 dB ~ -5 dB
See calibration results below
“Reminder: swipe tables left and right”

Calibration test results:

Current probes supplied by EUTTEST for FCC are supplied with factory calibration data at the time of shipment. The following chart shows the insertion loss test results for this product, which can be used for testing and third-party metrology calibration use.

F-230511-1008-1 Insertion Loss Calibration Results

Insertion Loss Calibration Results

Order No. EUTS0878

Note: This product is branded as FCC - Fischer Custom Communications, Inc. and is not Federal Communications Commission (FCC) certified.

Note: Please refer to the original FCC factory data sheet for any changes in product parameters.

FCC Official Authorized Dealer:

EUTTEST is an official FCC authorized dealer, and the full official name of the company is: Fischer Custom Communications, Inc.

Ltd. is authorized by FCC to sell all FCC products in China and provide technical service for the products sold.

Entered. 0/100

Sales Hotline:13425158926

Sales mailbox:sales@euttest.com

Sales WeChat account: euttest

EUTTEST-inquiry-wechat Shenzhen EUTTEST Technology Co.

Contact Sales by WeChat

Sales QQ:3127609248

[101] DISCLAIMER: Reproduction and redistribution by anyone without written permission from EUTTEST is prohibited.

Product parameters are subject to the manufacturer's final version.

If you like our products, please press Ctrl + D shortcut to favorite this product.