Standards Profile:

GB/T 17799.2-2023 is an electromagnetic compatibility EMC test standard, and applies to electronic products working in industrial environments EMC immunity test requirements specification. Below you can learn more about GB/T 17799.2-2023 test items, standard introduction, applicable test products and other related information. We also provide links to related EMC test instruments for reference.

Standard Name:

GB/T 17799.2-2023 General Standard for Electromagnetic Compatibility Part 2: Immunity Standards in Industrial Environments

Referenced in: IEC 61000-4-6:2016 standard.

GB/T 17799.2-2023 Which industrial products are applicable:

The purpose of GB/T 17799.2-2023 is to specify the immunity test requirements for continuous and transient, conducted and radiated disturbances and electrostatic discharges associated with electrical and electronic equipment used in industrial premises and directly connected to DC distribution grids or using batteries and used in industrial premises for which there is no dedicated product or product class immunity standard.

  • The electromagnetic compatibility (EMC) immunity requirements of this document apply to the following electrical and electronic equipment used in industrial locations, covering the frequency range from 0 Hz to 400 GHz. Tests are not required at frequencies where immunity requirements are not specified.
  • This general EMC immunity standard applies if there is no relevant specialized product or product class EMC immunity standard.
  • This document applies to electrical and electronic equipment operating in industrial premises (as defined in 3.7), both indoor and outdoor This document also applies to equipment connected directly to a direct current (DC) distribution network or powered by batteries and used in industrial premises.
  • This document specifies the immunity test requirements related to continuous and transient, conducted and radiated disturbances and electrostatic discharges for equipment within the scope of application.

Port definitions for industrial equipment:

GB/T 17799.2-2023 defines a variety of device ports, including AC power ports, DC power ports, signal ports, control ports, and enclosure ports.

GB/T 17799.2-2023 defines a variety of device ports

GB/T 17799.2-2023 defines a variety of device ports

EMS test items of GB/T 17799.2-2023:

GB/T 17799.2-2023 defines different EMC immunity test requirements for each type of equipment port, for details, see the test specification test levels shown below and the contents of the relevant reference standards:

Enclosure port immunity test program for industrial equipment:

<<<<提醒:左右滑动表格>>>>
serial numberEMS Test Programtest levelreferenced standardnotePerformance Rating
The following items are supplied by EUT TEST with test equipment and related accessories
1.1Industrial frequency magnetic field test instrument50 Hz, 30 A/mIEC61000-4-8Only suitable for products containing products that are sensitive to magnetic fieldsA
1.2Radio Frequency Electromagnetic Field Test Instruments, Amplitude Modulation80-1000 MHz

10 V/m

80% AM modulation (1kHz)

IEC 61000-4-3RMS without modulationA
1.3Radio Frequency Electromagnetic Field Test Instruments, Amplitude Modulation1.4-6 GHz

3 V/m

80% AM modulation (1kHz)

IEC 61000-4-3RMS without modulationA
1.4Electrostatic Discharge Test Equipment

Static Test Table

Contact discharge: ±4kV

Air discharge: ±8kV

IEC 61000-4-2B
<<<<提醒:左右滑动表格>>>>

Immunity test program for signal/control ports of industrial equipment:

<<<<提醒:左右滑动表格>>>>
serial numberEMS Test Programtest levelreferenced standardnotePerformance Rating
The following items are supplied by EUT TEST with test equipment and related accessories
2.1RF Common Mode Immunity Tester0.15-80 MHz

10V

80%AM Modulation

IEC 61000-4-6RMS without modulationA
2.2Surge Immunity Tester

Line-Ground

1.2/50μS (8/20μS)

±1 kV

IEC 61000-4-5B
2.3Electrical fast transient pulse group immunity test requirements±1kV

5/50 ns

5/100kHz

IEC 61000-4-4Use of capacitive coupling clipsB
<<<<提醒:左右滑动表格>>>>

Immunity test program for DC DC power input and output ports of industrial equipment:

<<<<提醒:左右滑动表格>>>>
serial numberEMS Test Programtest levelreferenced standardnotePerformance Rating
The following items are supplied by EUT TEST with test equipment and related accessories
3.1RF Common Mode Immunity Tester0.15-80 MHz

10V

80%AM Modulation

IEC 61000-4-6RMS without modulationA
3.2Surge Immunity Tester

Line-Ground

Line - Line

1.2/50μS (8/20μS)

±1 kV

±0.5 kV

IEC 61000-4-5B
3.3Electrical fast transient pulse group immunity test requirements±1kV

5/50 ns

5/100kHz

IEC 61000-4-4B
<<<<提醒:左右滑动表格>>>>

Immunity test program for AC power input and output ports of industrial equipment:

<<<<提醒:左右滑动表格>>>>
serial numberEMS Test Programtest levelreferenced standardnotePerformance Rating
The following items are supplied by EUT TEST with test equipment and related accessories
4.1RF Common Mode Immunity Tester0.15-80 MHz

10V

80%AM Modulation

IEC 61000-4-6RMS without modulationA
4.2Combined wave immunity test equipment

Voltage Transient Droop Immunity Test Apparatus

0%, 1 cycle

40% (10 cycles) - 70% (25 cycles)

IEC 61000-4-11

IEC 61000-4-34

Voltage variation at zero crossingB

C

4.3Voltage Interruption Test Equipment0%, 250 cyclesIEC 61000-4-11

IEC 61000-4-34

Voltage variation at zero crossingC
4.4Surge Immunity Tester

Line-Ground

Line - Line

1.2/50μS (8/20μS)

±2 kV

±1 kV

IEC 61000-4-5B
4.5Electrical fast transient pulse group immunity test requirements±2kV

5/50 ns

5/100kHz

IEC 61000-4-4B
<<<<提醒:左右滑动表格>>>>

Future or specific industrial products need to be considered for testing immunity experiments and experimental levels:

<<<<提醒:左右滑动表格>>>>
Test Item Namereferenced standardExperimental grades in cited standards
Ringing Wave TestIEC61000-4-123
harmonic (wave with frequency an integer multiple of the fundamental)

interharmonic wave

IEC 61000-4-133
Common mode conducted immunity below 150kHzIEC 61000-4-163
Slow damped oscillatory waveIEC61000-4-183
Below 150kHz Differential Mode Conducted HarassmentIEC 61000-4-194
DC power port voltage dips, interruptions and voltage variations testingIEC 61000-4-292
Broadband Nuisance TestIEC 61000-4-31await a decision
<<<<提醒:左右滑动表格>>>>

and GB/T 17799.2-2023 related test standards:

  • Immunity in residential, commercial and light industrial environments GB/T17799.1
  • Part 2: Immunity standards for industrial environments GB/T17799.2
  • Emissions in residential, commercial and light industrial environments GB17799.3
  • Part 4: Emissions in the industrial environment GB17799.4
  • Indoor equipment high altitude electromagnetic pulse (HEMP) immunity GB/T17799.5
  • Immunity in power plant and substation environments GB/Z17799.6
  • Part 7: Immunity requirements for equipment used to perform safety-related system functions (functional safety) in industrial locations GB/T 17799.7