Introduction:

In recent years, digital isolation chips are increasingly trusted by engineers in industrial, medical, automotive and other fields. Digital isolation chips are gradually replacing traditional optocoupler devices because of their small size, high integration, low power consumption, high communication speed and other notable features. Digital isolation chip is the core device in the system involving high voltage safety, so it needs to be strictly screened when leaving the factory. qpd partial discharge test as one of the main items of the digital isolator certification test, understand the purpose and significance of the partial discharge test can better understand the function of the digital isolator.

Qpd partial discharge test index requirements

Qpd partial discharge test index requirements

UL1577 safety standard clearly stipulates that the products must be tested under 60s or 1.2 times of the insulation voltage withstand condition corresponding to the product specification when leaving the factory, and the products can only leave the factory after passing the high voltage test. Taking the product with isolation strength of 3000Vrms as an example, it needs to undergo the high-voltage test of 60s under AC voltage of 3000Vrms and 60Hz frequency or 1s under AC voltage of 3600Vrms and 60Hz frequency at the time of shipment, and can be shipped out of the factory only after passing the test.

The detection method of the high voltage test specified in UL1577 is to detect the leakage current of the insulation layer. If the insulation layer of the digital isolation chip can withstand the test high voltage, then the detected leakage current of the insulation layer will be relatively small, the value is usually uA level, this is because the application of low-frequency AC high voltage, as long as the isolation of the two sides of the existence of a certain amount of parasitic capacitance, there will be the existence of AC leakage current. However, if the insulating layer of the digital isolation chip is not able to withstand the corresponding high voltage, then the insulating layer will produce uncontrollable leakage current because of the high voltage, which finally leads to the damage of the isolation band.

Purpose and significance of Qpd partial discharge test

Usually digital isolation chip insulation layer in the production of manufacturing time has a high degree of environmental cleanliness requirements, there can not be bubbles or the existence of voids, so as to ensure good insulation effect and long insulation life. However, in the actual production process, it is difficult to ensure that all chips 100% ensure that the insulation layer has no air bubbles or voids, and the existence of these voids or bubbles will lead to a decline in insulation performance, but these voids or bubbles can not be detected by detecting high-voltage leakage current method. The purpose and significance of partial discharge test is when the high voltage is added to the insulation medium at both ends, because of the existence of these bubbles or voids, will produce a partial discharge (Qpd: Partial Discharge), slight partial discharge on the insulation of the power equipment, the impact of the insulation strength of the smaller, the insulation strength of the decline is slower; and a strong localized discharge, will make the insulation strength decline very quickly. This is an important factor in the damage to the insulation of high-voltage power equipment. Partial discharge will be accompanied by the generation of electric pulse, ultrasonic, electromagnetic radiation, light, chemical reaction, and cause local heating and other phenomena, is the harbinger of the aging of electrical components. The applied voltage for partial discharge detection is not the insulation withstand voltage value, but the working voltage added to the insulation layer, because only the working voltage acts on the insulation layer for a long period of time, and may cause repeated charging and discharging of defective products, which ultimately leads to premature failure of the insulation layer. For this reason, the VDE 0884-10 or VDE 0884-11 safety standards require a partial discharge test in addition to a high-voltage leakage current test during the factory test. The test voltage for the partial discharge test is 1.875 times the peak operating voltage, the test time is 1s and the target value of the test result is the size of the leakage charge.

Qpd partial discharge test circuit

Partial Discharge Test Circuit

Digital Isolation Chip Factory Isolated + Qpd High Voltage Test Waveforms

Digital Isolation Chip Factory Isolated + Qpd High Voltage Test Waveforms

For the above isolation voltage test and partial discharge test, you can use our agent to sell theHT9464 maybe HT-9464M Test master for certification testing up to AC 10kV rms.

According to customer requirements, our company can customize the configuration of the tester + sorter multi-channel test system, can be automatically completed in the production line of digital isolator Qpd partial discharge multi-channel automated testing.

Multi-Channel Qpd Automation Testing with Sorting Machines

Multi-Channel Qpd Automation Testing with Sorting Machines

The system comes with a Ramp climb test mode to help digital isolator developers determine the maximum isolation voltage the isolator can withstand and the VDE standard test pattern.

Ramp climb test mode and VDE test mode.

Ramp climb test mode and VDE test mode.